221001 - Gas Odorant Injection System
For low-volume and high-pressure applications at CNG filling, city gas distribution, LPG and biogas companies.
- Fully Automatic dosing proportional to gas flow rate
- High range ability (100:1 turndown ratio)
- Precision odorizing (1% accuracy) with a wide flow volume range
- Gas flow volume from 100 SCMH to 100000 SCMH
- For pipelines with pressure 5 – 4500 PSI (0.3 – 300 Bar)
Current Installation Lead Time: 2-4 Weeks
Trusted By
Zero Odorant Leakage During Operation or Maintenance
The odorant system is completely sealed & enclosed. This eliminates the common odorant leakage and associated smell complaints seen on other odorizing systems.
No Moving Parts. Long Lasting. Unlike Other Solutions In the Market
A modular solid-state manifold with minimal tube joints and no moving parts assures long-lasting performance. This also makes it extremely easy to maintain and operate.
Fully Automatic With PLC and A 7” Touchscreen HMI
The system is fully controllable via a PLC (Delta/Equivalent)
With the fully automatic mode, the machine auto-adjusts the dosing interval even if your flow rate increases or decreases. If the pipeline gas flow rate varies, the pump adjusts the time per stroke cycle to maintain a constant odorant flow.
This ensures a constant odorant concentration regardless of upstream changes to gas flow. With a maximum of 25 strokes/minute, there is virtually no risk of fluid flashing from pressure drop.
The 7” Touchscreen [Delta/Equivalent] HMI lets you intuitively monitor & control the following parameters:
- Pump dosing frequency
- Pump stroke count
- Dosing Totalizer
- Compressor ON/OFF
- Dosing flow rate(Optional)
- Gas flow rate manual setting/ Real Flow rate from Flow meter (optional)
- Tank Level (Optional)
- Tank Pressure (Optional)
Solid-State Modular Design
The Odorizer utilizes a solid-state modular designed pump assembly which minimizes joints and fittings. The hydraulic/pneumatic section of the plunger pump is isolated from the odorant section.
The only replacement items are the hydraulic piston plunger seals, engineered for long-lasting performance, and a filter to be replaced annually.
Once-A-Year Maintenance
All it needs is a new hydraulic piston seal and odorant liquid filter. And both of those are extremely easy operations.
Self-Monitoring and Real-Time Alarms
The system is self-monitoring and generates an external alarm to control room PCs and smartphones(Optional), if the odorizing system does not odorize within the configured settings. Alarm conditions are stored and time-stamped in non-volatile memory like SD card (Optional).
For whatever reason, if the system fails to dosing with the configured settings, its smart logic will send an alarm to the control room PCs and operator smartphones(Optional) in real time.
General Specifications
Max. Odorant Injection | 0.2-1 liter /Hr. |
Max. Working Pressure | 6-8 bar(g) depends on Pump Discharge pressure requirements |
Working Temperature | 0 °C to +60 °C |
GAS Flow rate | 200 to 20000 + SCMH |
Dosing Flow rates | Proportional to gas flow rate (Real/Fixed) |
Odorant | Ethyl Mercaptan /TBM+MES (Client scope) |
Dosing pressure | 0.300 Bar Max to 300 Bar Max. |
Control system | Automatic dosing proportional to Real/Fixed flow rate. Time based dosing system also available |
Control Panel | PLC based Electronic Controller, Safe area installation with PLC, 7” Touch Screen HMI, 24 VDC SMPS, Output relays (+Push buttons) |
Control Panel MOC | Powder coated MS cabinet |
Communication with Control room | RS 485 RTU We will provide you Modbus addresses(Optional) |
Tank Capacity | 200 Liter(Min. recommended) /500 Liter /1000 Liters as per client’s requirement |
Tank MOC | 304 Stainless Steel |
Tank with | Pressure Safety valves, Pressure gauge, Check valves, Magnetic Level gauge, Level Transmitter (Optional), Pressure Transmitter (Optional) |
Pump Cabinet | Weather proof |
Pump Cabinet MOC | 304 Stainless Steel |
Pump Cabinet with | Regulators, Filters, Pumps, Solenoid valves, Pressure Safety valves, Check valves, Calibration column, 1/2/3 Dosing Flow transmitters (Optional) |
Pumps | For Odorant Dosing (1 working & 1 standby) or as per client |
Complete Odorant skid with | Tank, Pump Cabinet, Scrubber, Flame Arrestor, Canopy, Secondary containment tray |
Sight flow indicators | 1 for LP stream, 1 for MP stream & 1 for HP stream |
Sight flow indicators MOC | SS 316 & Toughened glass |
Power supply Requirement | 230 VAC from UPS (Client’s scope) |
Battery (Optional) | 24 VDC battery backup for 12 hour |
Solar system (Optional) | 325 watt solar Panel for additional power source |